arcserve-KB : Failed to write data. System error (The specified network name is no longer available (64)

Last Update: 2015-12-16 12:31:53 UTC

Product : UDP Appliance 7000

Description:
Backup fails.

 

Error Message: 
Operation (create, close, read, write) on file xxxxx failed. Error code 64. The specified network name is no longer available.'
Failed to write data. System error =(The specified network name is no longer available (64)

Solution: 

  • The backup destination for the UDP backup is on the remote NAS box.
  • In this scenario, UDP appliance server and NAS box are connected to two different switches.
  • Ensure that the Backup Destination (Windows Server or NAS device) is online and available during the backup window.
  • Check the backup destination (NAS Device) to see if there are any performance issues or system resource bottlenecks.
  • Also check the Windows Event Logs for any network related errors.
  • Check if the failure is related to a specific node or all the nodes which are being backed up to the NAS Device.
  • If the backup of all the nodes have a problem, then check if there is any problem with the switches to which UDP Appliance or NAS box is connected.

 

Was this article helpful?
0 out of 0 found this helpful